Burners, Controls
and other Accessories
|
Burners
For new or used boilers, these complete upgrade packages
from 800,000 BTUs to 200,000,000 BTUs include all fuels.
Additionally, these units include high turndown capability
(up to 10:1) along with low NOx capability, integral
load tracking, lead lag control of multiple boilers,
and O2 trim.
We offer burners from:
|
|
|
Controls
For controlling combustion, draft, and multiple
boiler sequencing with
the capability for supervisory control and data acquisition.
An entire plant including boilers, chillers, cooling
towers, and auxiliary equipment may be monitored and
operated from a single location. Data gathered is saved
for later review and used to print out customized log
sheets and fuel usage comparisons.
Monitoring
Systems
Lighted annunciator panels show, at a glance, exactly
what your boiler system is doing. Then, they automatically
dial a phone, phone paging system, or pocket pager advising
the responsible party of an emergency condition.
Systems monitor:
- Flame
Failure
-
Power Outage
-
High Pressure or Temperature
-
Low Pressure or Temperature
-
Low Water
-
Boiler Water Conductivity
- Low
Chemical Tank Level
-
High Stack Temperature
-
Compressor Operation
- Access
Control Condition
- Security
Operation
- Fire
Protection Operation
- Phone
Line Operation
|
PBBS
carries controls and monitoring systems by:
|
|
|
 |
Heat
Exchangers
Heat
exchangers are used for heating or cooling liquids
for process systems, heat recovery, and comfort
systems using steam or liquids.
Pumps
Circulators,
horizontal, vertical in-line and multi-stage and
metering pumps.
|
PBBS
offers Heat Exchangers and Pumping equipment from:
|
|
Oxygen Trim Systems
Are designed to keep your boiler in tune in spite of
changes in atmospheric conditions that can cost you
money in wasted fuel. In fact, an 8% change in barometric
pressure could result in a full 1% change in your boilers
flue gas oxygen level. That minor change in fuel air
ratio can cost you thousands of dollars a year depending
on the size of your boiler. An oxygen trim system can
save you that money by continually tuning your boiler
while in operation.
The continuous adjustment in your boilers fuel-air
ratio by an Oxygen trim system is accomplished by
measuring the oxygen level in your flue gas (excess
air). If the O2 varies from the original tune up
settings, adjustments are automatically made to either
the air damper, or the burner fuel flow using a separate
trim actuator. The Hays Cleveland O2 trim system
provides this money saving control with a variety
of easy to maintain options.
More precise systems, such as the Auto-Flame Exhaust
Gas Analyzer (EGA), go one step further, monitoring
not only Oxygen, but Carbon Dioxide (CO2), and Carbon
Monoxide (CO) as well. This 3-parameter trim system
by Auto-Flame insures that the O2 and CO2, which
are directly related, are tracking as they should,
and if the numbers don’t work, re-adjusts the
burner to insure that it is operating safely. The
monitoring of the CO provides additional information
to the trim response, and the EGA can maximize the
performance of your burner while minimizing the CO.
This is all done by use of the Auto-Flame parallel
positioning servomotors.
But Oxygen trim is not for everyone. Depending on
your boilers load and run time, an oxygen trim system
may not provide the performance expected. Oxygen
trim systems are not “boiler tune-up machines” as
some would have you believe. Your boiler should be
tuned up prior to installing an O2 trim, allowing
the O2 trim to keep your boiler in tune.
So call your PBBS representative and ask if Oxygen
Trim is right for your boiler.
PBBS carries O2 Trim
Systems by:
|
|
Steam
Specialties
Steam specialties include control valves for
pressure and temperature, steam regulators, reducing
and relief valves, steam traps, flow switches and
liquid level controls.
PBBS offers specialty steam equipment from the
following manufacturers:
|
|
|
|
Venting
Systems
| PBBS
offers a full line of stacks, vents, grease
ducts and auto-draft vent systems from AMPCO
and Tjernlund. |
 |
|
|